Call Us 24/7

+86 13353340627

Send Us Mail

info@kunji-electric.com

Our Location

Wenzhou City,Zhejiang Province,China

underground transformer Substation

Type:Power

Structure:Protection

Certification:ISO9001:2000, CCC

Form:Partly-welded Type

Operation Voltage:High Voltage

รายละเอียดเพิ่มเติม

Product Description

The Combined Substation is an integrated power distribution solution that consolidates various components into a single unit. It efficiently manages electrical energy acceptance, distribution, and control within a compact design, offering versatility and ease of installation.

Technical parameters:

No. Item Unit Parameters
1 Rated voltage kV 12
2 Rated frequency Hz 50
3 Rated current of load switch A 630
4 Main circuit thermal current kA 20
5 Main circuit dynamic current kA 50
6 Rated making current of main circuit kA 50
7 Rated active load breaking current 630
8 Rated ring closed breaking current A 630
9 5% of rated active load breaking current A 31.5
10 Rated breaking current of cable charging A 10
11 Rated no-load breaking current of transformer A 1600KVAq
12 Rated breaking current of fuse kA 31.5
13 Rated transfer current A 1500
14 Mechanical duration times 10000
15 1min power frequency withstand voltage to earth/between phases/disconnecting fracture kV 42/48
16 Lightning impulse withstand voltage to earth/between phases/disconnecting fracture kV 75/85
17 Rated pressure of SF6 (20ºCsurface pressure) Mpa 0.045
18 Annual leakage rate of SF6 ≤0.2%

Underground Combined Power Transformer Substation OEM ODMUnderground Combined Power Transformer Substation OEM ODMUnderground Combined Power Transformer Substation OEM ODMWORKING CONDITION

 

PRODUCTION DETAILS

Underground Combined Power Transformer Substation OEM ODMUnderground Combined Power Transformer Substation OEM ODM

Use environment
1. Altitude: ≤1000 meters.
2. Temperature: High temperature: +40ºC; Low temperature: -45ºC; High monthly average temperature: +30ºC; High annual average temperature: +20ºC.
3. Environment: No explosive, corrosive liquids, gases, or dust. Installation sites should be free from severe vibrations and allow complete submersion in water for a certain period.
4. Ground acceleration induced by earthquakes (Ag): Horizontal direction <3m/s; Vertical direction <1.5m/s.
5. Power supply voltage waveform: Approximately sine wave.
6. Three-phase power supply symmetry: For three-phase underground transformers, the three-phase power supply voltage should be approximately symmetrical.

รีวิว

ยังไม่มีบทวิจารณ์

มาเป็นคนแรกที่วิจารณ์ “underground transformer Substation”

อีเมลของคุณจะไม่แสดงให้คนอื่นเห็น ช่องข้อมูลจำเป็นถูกทำเครื่องหมาย *

Download

Product Description

The Combined Substation is an integrated power distribution solution that consolidates various components into a single unit. It efficiently manages electrical energy acceptance, distribution, and control within a compact design, offering versatility and ease of installation.
Technical parameters:
No. Item Unit Parameters
1 Rated voltage kV 12
2 Rated frequency Hz 50
3 Rated current of load switch A 630
4 Main circuit thermal current kA 20
5 Main circuit dynamic current kA 50
6 Rated making current of main circuit kA 50
7 Rated active load breaking current 630
8 Rated ring closed breaking current A 630
9 5% of rated active load breaking current A 31.5
10 Rated breaking current of cable charging A 10
11 Rated no-load breaking current of transformer A 1600KVAq
12 Rated breaking current of fuse kA 31.5
13 Rated transfer current A 1500
14 Mechanical duration times 10000
15 1min power frequency withstand voltage to earth/between phases/disconnecting fracture kV 42/48
16 Lightning impulse withstand voltage to earth/between phases/disconnecting fracture kV 75/85
17 Rated pressure of SF6 (20ºCsurface pressure) Mpa 0.045
18 Annual leakage rate of SF6 ≤0.2%
Underground Combined Power Transformer Substation OEM ODMUnderground Combined Power Transformer Substation OEM ODMUnderground Combined Power Transformer Substation OEM ODMWORKING CONDITION
  PRODUCTION DETAILS Underground Combined Power Transformer Substation OEM ODMUnderground Combined Power Transformer Substation OEM ODM Use environment 1. Altitude: ≤1000 meters. 2. Temperature: High temperature: +40ºC; Low temperature: -45ºC; High monthly average temperature: +30ºC; High annual average temperature: +20ºC. 3. Environment: No explosive, corrosive liquids, gases, or dust. Installation sites should be free from severe vibrations and allow complete submersion in water for a certain period. 4. Ground acceleration induced by earthquakes (Ag): Horizontal direction <3m/s; Vertical direction <1.5m/s. 5. Power supply voltage waveform: Approximately sine wave. 6. Three-phase power supply symmetry: For three-phase underground transformers, the three-phase power supply voltage should be approximately symmetrical.