Pad Mounted Transformer Compact Substation

Shell Material: Steel Plate
Rated Voltage: 4-24 Kv
Certification: ISO9001:2000, CCC,CE
Form: Partly-welded Type
Rated Capacity: 15 to 3500kVA
Production Capacity: 300pieces/Month

Phase number: three phases

รายละเอียดเพิ่มเติม

Product Description

Large Capacity 15kv to 3000kVA Compact Transformer Substation Pad Mounted Transformer

The shell design adopts advanced technology, featuring solidity, thermal insulation, corrosion resistance, dustproof, waterproof, and other characteristics. Various shell materials such as aluminum alloy plate, steel plate, composite plate, stainless steel plate, and non-metallic materials are available for selection.The high-voltage switchgear options for incoming, metering, and outgoing lines include XGN15, HXGN17, or KYN28A. For low-voltage switchgear, options such as GGD, GCS, or MNS are chosen for low-voltage incoming lines, reactive power compensation, and low-voltage outgoing lines.

 

Name Unit Technical Parameters
Rated voltage kV 10/0.4(Medium/Low)
Maximum operating kV 12(Medium/Low)
Rated frequency Hz 50
Rated capacity kVA 50-4000
1 minute power frequency withstand voltage kV 35
Lightning impulse voltage kV 75
Cooling method ONAN
High-voltage fuse breaking current reserve kA 50
Plug-in fuse breaking current kA 2.5
Ambient temperature ºC -35~+40
Coil allowable temperature rise ºC 65
No-load voltage regulation ±5%or±2*2.5%
Noise level db 50
Protection class IP43

 

WORKING CONDITIONS

1、Altitude: Not exceeding 2000 meters.

2、Ambient temperature:

High temperature: +40ºC; Low temperature: -45ºC; High monthly average temperature: +30ºC; High annual average     temperature: +20ºC.

3、Installation environment: No explosive, corrosive liquids, gases, or dust. The installation site should be free from severe vibrations and allows operation submerged in water for a certain period or completely.

4、Ground acceleration induced by earthquake (Ag):

Horizontal direction lower than 3m/s; Vertical direction lower than 1.5m/s.

5、Power supply voltage waveform: Approximately sinusoidal.

6、Three-phase power supply symmetry:

For three-phase underground transformers, the three-phase power supply voltage should be roughly symmetrical.

รีวิว

ยังไม่มีบทวิจารณ์

มาเป็นคนแรกที่วิจารณ์ “Pad Mounted Transformer Compact Substation”

อีเมลของคุณจะไม่แสดงให้คนอื่นเห็น ช่องข้อมูลจำเป็นถูกทำเครื่องหมาย *

Download
Product Description Large Capacity 15kv to 3000kVA Compact Transformer Substation Pad Mounted Transformer The shell design adopts advanced technology, featuring solidity, thermal insulation, corrosion resistance, dustproof, waterproof, and other characteristics. Various shell materials such as aluminum alloy plate, steel plate, composite plate, stainless steel plate, and non-metallic materials are available for selection.The high-voltage switchgear options for incoming, metering, and outgoing lines include XGN15, HXGN17, or KYN28A. For low-voltage switchgear, options such as GGD, GCS, or MNS are chosen for low-voltage incoming lines, reactive power compensation, and low-voltage outgoing lines.  
Name Unit Technical Parameters
Rated voltage kV 10/0.4(Medium/Low)
Maximum operating kV 12(Medium/Low)
Rated frequency Hz 50
Rated capacity kVA 50-4000
1 minute power frequency withstand voltage kV 35
Lightning impulse voltage kV 75
Cooling method ONAN
High-voltage fuse breaking current reserve kA 50
Plug-in fuse breaking current kA 2.5
Ambient temperature ºC -35~+40
Coil allowable temperature rise ºC 65
No-load voltage regulation ±5%or±2*2.5%
Noise level db 50
Protection class IP43
 
WORKING CONDITIONS 1、Altitude: Not exceeding 2000 meters. 2、Ambient temperature: High temperature: +40ºC; Low temperature: -45ºC; High monthly average temperature: +30ºC; High annual average     temperature: +20ºC. 3、Installation environment: No explosive, corrosive liquids, gases, or dust. The installation site should be free from severe vibrations and allows operation submerged in water for a certain period or completely. 4、Ground acceleration induced by earthquake (Ag): Horizontal direction lower than 3m/s; Vertical direction lower than 1.5m/s. 5、Power supply voltage waveform: Approximately sinusoidal. 6、Three-phase power supply symmetry: For three-phase underground transformers, the three-phase power supply voltage should be roughly symmetrical.