Call Us 24/7

+86 13353340627

Send Us Mail

info@kunji-electric.com

Our Location

Wenzhou City,Zhejiang Province,China

Low Voltage Arrester Series Polymeric

Application: Insulators, Electrical Winding Insulation, Winding Wire Coating Insulation, Electrical Base, Shell, Switch Baseplate
Type: Insulation Tape
Chemistry: Organic Insulation
Material: Rubber
Thermal Rating: 220 220
Maximum Voltage: <10KV

รายละเอียดเพิ่มเติม

Product Description

 Low Voltage Surge Lightning Arrester  Parameters

el System Rated voltage Arrester rated voltage MCOV DC U1mA 8/20us ligntninh impulse residual voltage 2ms rectangular wave allowed current capacity 4,10us high current impulse withstand
                      kV(r.m.s) ≮kV ≯kV
HY5WS-3.8/15    3 3.8 2 7.5 15 75A 40kA
HY5WS-5/15 5 4 8 15 90A 65kA
HY5WS-7.6/30    6 7.6 4 15 30 75A 40kA
HY5WS-10/30 10 8 15 30 90A 65kA
HY5WS-12.7/50 10 12.7 6.6 25 50 75A 40kA
HY5WS-17/50 17 13.6 25 50 90A 65kA

WORKING CONDITIONSa) Ambient air temperature within the range of -55ºC to +50ºC.

b) Altitude not exceeding 2000m.

c) Frequency of the A.C. Power supply not less than 48Hz and not exceeding 62Hz.

d) Power frequency voltage applied continuously between the terminals of the arrester not exceeding its continuous operating voltage.

e) Maximum wind speed not exceeding 35m/s.

f) Earthquake intensity not exceeding 7 degrees.

PRODUCTION DETAILS

Low Voltage Surge Lightning Arrester Metal Oxide Gapless ZnO Polymeric Type 500V

รีวิว

ยังไม่มีบทวิจารณ์

มาเป็นคนแรกที่วิจารณ์ “Low Voltage Arrester Series Polymeric”

อีเมลของคุณจะไม่แสดงให้คนอื่นเห็น ช่องข้อมูลจำเป็นถูกทำเครื่องหมาย *

Download

Product Description

 Low Voltage Surge Lightning Arrester  Parameters
el System Rated voltage Arrester rated voltage MCOV DC U1mA 8/20us ligntninh impulse residual voltage 2ms rectangular wave allowed current capacity 4,10us high current impulse withstand
                      kV(r.m.s) ≮kV ≯kV
HY5WS-3.8/15    3 3.8 2 7.5 15 75A 40kA
HY5WS-5/15 5 4 8 15 90A 65kA
HY5WS-7.6/30    6 7.6 4 15 30 75A 40kA
HY5WS-10/30 10 8 15 30 90A 65kA
HY5WS-12.7/50 10 12.7 6.6 25 50 75A 40kA
HY5WS-17/50 17 13.6 25 50 90A 65kA
WORKING CONDITIONSa) Ambient air temperature within the range of -55ºC to +50ºC. b) Altitude not exceeding 2000m. c) Frequency of the A.C. Power supply not less than 48Hz and not exceeding 62Hz. d) Power frequency voltage applied continuously between the terminals of the arrester not exceeding its continuous operating voltage. e) Maximum wind speed not exceeding 35m/s. f) Earthquake intensity not exceeding 7 degrees. PRODUCTION DETAILS Low Voltage Surge Lightning Arrester Metal Oxide Gapless ZnO Polymeric Type 500V