NT low voltage H.R.C. fuse features light in weight, small in size, low in power loss and high in breaking capacity. This product has been widely used in overload and short circuit protection of electric installation. This product conforms to IEC 60269 standards with all of the rating at the world advanced level.

Technical Parameters

Model/Size Rated Voltage(V)  

Rated current Specifications(A)

 

Overall dimension
A D E H H1 H2
NH00C 500/690 4,6,10,20,25,32,40,50,63,80,100 78 52 21 53 15 35
NH00  500/690 (4-100),125,160 78 53 30  60 15  48
NH1  500/690 80,100,125,160,200,224,250 135 72 48  65 20 48
NH2  500/690 125,160,200,224,250,300,315,355,400 150 72 58  72 25 58
NH3  500/690 315,355,400,425,500,630 150 74 67 82 32  71

 

WORKING CONDITIONS

no more than 2,000 meters above sea level is required,

Normal operating temperature range is -5 ~ 40ºC, limit range is -40 ~ 70ºC;

At the same tielative humidity should be 30% ~ 90% at room temperature.

Special considerations may be required in the design and use of surge protectors placed under abnormal service conditions, which should be paid attention to.

รีวิว

ยังไม่มีบทวิจารณ์

มาเป็นคนแรกที่วิจารณ์ “Fuses for low voltage switchgear”

อีเมลของคุณจะไม่แสดงให้คนอื่นเห็น ช่องข้อมูลจำเป็นถูกทำเครื่องหมาย *

Download
Product Description NT low voltage H.R.C. fuse features light in weight, small in size, low in power loss and high in breaking capacity. This product has been widely used in overload and short circuit protection of electric installation. This product conforms to IEC 60269 standards with all of the rating at the world advanced level. Technical Parameters
Model/Size Rated Voltage(V)   Rated current Specifications(A)   Overall dimension
A D E H H1 H2
NH00C 500/690 4,6,10,20,25,32,40,50,63,80,100 78 52 21 53 15 35
NH00  500/690 (4-100),125,160 78 53 30  60 15  48
NH1  500/690 80,100,125,160,200,224,250 135 72 48  65 20 48
NH2  500/690 125,160,200,224,250,300,315,355,400 150 72 58  72 25 58
NH3  500/690 315,355,400,425,500,630 150 74 67 82 32  71
  WORKING CONDITIONS
no more than 2,000 meters above sea level is required, Normal operating temperature range is -5 ~ 40ºC, limit range is -40 ~ 70ºC; At the same tielative humidity should be 30% ~ 90% at room temperature. Special considerations may be required in the design and use of surge protectors placed under abnormal service conditions, which should be paid attention to.