Звоните нам 24 часа в сутки 7 дней в неделю

+86 13353340627

Отправить нам письмо

info@kunji-electric.com

Наше местоположение

Город Вэньчжоу, провинция Чжэцзян, Китай

underground transformer Substation

Type:Power

Structure:Protection

Certification:ISO9001:2000, CCC

Form:Partly-welded Type

Operation Voltage:High Voltage

Описание

Описание товара

The Combined Substation is an integrated power distribution solution that consolidates various components into a single unit. It efficiently manages electrical energy acceptance, distribution, and control within a compact design, offering versatility and ease of installation.

Technical parameters:

Нет. Артикул Единица Parameters
1 Rated voltage кВ 12
2 Номинальная частота Гц 50
3 Rated current of load switch A 630
4 Main circuit thermal current кА 20
5 Main circuit dynamic current кА 50
6 Rated making current of main circuit кА 50
7 Rated active load breaking current 630
8 Rated ring closed breaking current A 630
9 5% of rated active load breaking current A 31.5
10 Rated breaking current of cable charging A 10
11 Rated no-load breaking current of transformer A 1600KVAq
12 Rated breaking current of fuse кА 31.5
13 Rated transfer current A 1500
14 Mechanical duration times 10000
15 1min power frequency withstand voltage to earth/between phases/disconnecting fracture кВ 42/48
16 Lightning impulse withstand voltage to earth/between phases/disconnecting fracture кВ 75/85
17 Rated pressure of SF6 (20ºCsurface pressure) Mpa 0.045
18 Annual leakage rate of SF6 ≤0.2%

Underground Combined Power Transformer Substation OEM ODMUnderground Combined Power Transformer Substation OEM ODMUnderground Combined Power Transformer Substation OEM ODMWORKING CONDITION

 

ПРОИЗВОДСТВЕННЫЕ ДЕТАЛИ

Underground Combined Power Transformer Substation OEM ODMUnderground Combined Power Transformer Substation OEM ODM

Use environment
1. Altitude: ≤1000 meters.
2. Temperature: High temperature: +40ºC; Low temperature: -45ºC; High monthly average temperature: +30ºC; High annual average temperature: +20ºC.
3. Environment: No explosive, corrosive liquids, gases, or dust. Installation sites should be free from severe vibrations and allow complete submersion in water for a certain period.
4. Ground acceleration induced by earthquakes (Ag): Horizontal direction <3m/s; Vertical direction <1.5m/s.
5. Power supply voltage waveform: Approximately sine wave.
6. Three-phase power supply symmetry: For three-phase underground transformers, the three-phase power supply voltage should be approximately symmetrical.

Отзывы

Отзывов пока нет.

Будьте первым, кто оставил отзыв на “underground transformer Substation”

Ваш адрес email не будет опубликован. Обязательные поля помечены *

Скачать

Описание товара

The Combined Substation is an integrated power distribution solution that consolidates various components into a single unit. It efficiently manages electrical energy acceptance, distribution, and control within a compact design, offering versatility and ease of installation.
Technical parameters:
Нет. Артикул Единица Parameters
1 Rated voltage кВ 12
2 Номинальная частота Гц 50
3 Rated current of load switch A 630
4 Main circuit thermal current кА 20
5 Main circuit dynamic current кА 50
6 Rated making current of main circuit кА 50
7 Rated active load breaking current 630
8 Rated ring closed breaking current A 630
9 5% of rated active load breaking current A 31.5
10 Rated breaking current of cable charging A 10
11 Rated no-load breaking current of transformer A 1600KVAq
12 Rated breaking current of fuse кА 31.5
13 Rated transfer current A 1500
14 Mechanical duration times 10000
15 1min power frequency withstand voltage to earth/between phases/disconnecting fracture кВ 42/48
16 Lightning impulse withstand voltage to earth/between phases/disconnecting fracture кВ 75/85
17 Rated pressure of SF6 (20ºCsurface pressure) Mpa 0.045
18 Annual leakage rate of SF6 ≤0.2%
Underground Combined Power Transformer Substation OEM ODMUnderground Combined Power Transformer Substation OEM ODMUnderground Combined Power Transformer Substation OEM ODMWORKING CONDITION
  ПРОИЗВОДСТВЕННЫЕ ДЕТАЛИ Underground Combined Power Transformer Substation OEM ODMUnderground Combined Power Transformer Substation OEM ODM Use environment 1. Altitude: ≤1000 meters. 2. Temperature: High temperature: +40ºC; Low temperature: -45ºC; High monthly average temperature: +30ºC; High annual average temperature: +20ºC. 3. Environment: No explosive, corrosive liquids, gases, or dust. Installation sites should be free from severe vibrations and allow complete submersion in water for a certain period. 4. Ground acceleration induced by earthquakes (Ag): Horizontal direction <3m/s; Vertical direction <1.5m/s. 5. Power supply voltage waveform: Approximately sine wave. 6. Three-phase power supply symmetry: For three-phase underground transformers, the three-phase power supply voltage should be approximately symmetrical.