Сертификация: CCC, ISO9001

Shell Material:Steel Plate

Installation:Fixed

Structure:Withdrawable

Описание

Обзор

The MNS series distribution cabinet, renowned for its reliability, is a modular, multifunctional low-voltage solution tailored for industrial applications. Capable of supporting systems up to 4000A, it provides robust protection for both personnel and equipment safety, thanks to its flexible cabinet structure and humanized design.

 

Типы значения

 

Параметры продукта

Number GB7251.1-2005 Low-voltage switchgear and control equipment (T TA)

EC60439 《Low-voltage switchgear and control equipment》

1 Overvoltage category IV III
2 pollution level 3
3 Rated working voltage (Ue) (V) Rated working voltage (Ue) (V) 400/660
4 Rated insulation voltage (Ui) (V) Rated insulation voltage (Ui) (V) 660/1000
5 Rated frequency(Hz) Rated frequency(Hz) 50(60)
6 horizontal bus Номинальный ток ≤5000A
7 Rated short-time withstand current (lcw) (kA) 50,65,80(1s valid value)
8 Rated peak withstand current (pk) (kA) 105,140,176(0.1s maximum value)
9 vertical bus Rated maximum working current ≤1000A
10 Rated short-time withstand current (lcw) (kA) 50kA
11 Rated peak withstand current 105kA
12 Enclosure rating IP30 IP40(Special Instructions)

 

Размер продукта Описание

 

Рабочие условия

Here is the English description regarding the application, implementation standards, environmental conditions, installation site, and altitude for power distribution and motor control:

1. Application:Power distribution, motor control.
2. Implementation standards:IEC439, GB7251.1.
3. Environmental conditions:Operating temperature range: -5 ℃ to 40 ℃. At 40 ℃, the relative humidity should not exceed 50%. At lower temperatures, higher relative humidity is permitted, and occasional condensation may occur (e.g., 90% at 20 ℃).
4. Installation site:Indoor.
5. Altitude:≤ 2000 meters.
Note: If unable to meet the above conditions, users should communicate their requirements to the manufacturer at the time of ordering.

Отзывы

Отзывов пока нет.

Будьте первым, кто оставил отзыв на “MNS Series Switchgear”

Ваш адрес email не будет опубликован. Обязательные поля помечены *

Скачать
Обзор The MNS series distribution cabinet, renowned for its reliability, is a modular, multifunctional low-voltage solution tailored for industrial applications. Capable of supporting systems up to 4000A, it provides robust protection for both personnel and equipment safety, thanks to its flexible cabinet structure and humanized design.   Типы значения   Параметры продукта
Number GB7251.1-2005 Low-voltage switchgear and control equipment (T TA) EC60439 《Low-voltage switchgear and control equipment》
1 Overvoltage category IV III
2 pollution level 3
3 Rated working voltage (Ue) (V) Rated working voltage (Ue) (V) 400/660
4 Rated insulation voltage (Ui) (V) Rated insulation voltage (Ui) (V) 660/1000
5 Rated frequency(Hz) Rated frequency(Hz) 50(60)
6 horizontal bus Номинальный ток ≤5000A
7 Rated short-time withstand current (lcw) (kA) 50,65,80(1s valid value)
8 Rated peak withstand current (pk) (kA) 105,140,176(0.1s maximum value)
9 vertical bus Rated maximum working current ≤1000A
10 Rated short-time withstand current (lcw) (kA) 50kA
11 Rated peak withstand current 105kA
12 Enclosure rating IP30 IP40(Special Instructions)
  Размер продукта Описание   Рабочие условия Here is the English description regarding the application, implementation standards, environmental conditions, installation site, and altitude for power distribution and motor control: 1. Application:Power distribution, motor control. 2. Implementation standards:IEC439, GB7251.1. 3. Environmental conditions:Operating temperature range: -5 ℃ to 40 ℃. At 40 ℃, the relative humidity should not exceed 50%. At lower temperatures, higher relative humidity is permitted, and occasional condensation may occur (e.g., 90% at 20 ℃). 4. Installation site:Indoor. 5. Altitude:≤ 2000 meters. Note: If unable to meet the above conditions, users should communicate their requirements to the manufacturer at the time of ordering.