Subestação compacta de transformador montado na base

Shell Material: Steel Plate
Rated Voltage: 4-24 Kv
Certification: ISO9001:2000, CCC,CE
Form: Partly-welded Type
Rated Capacity: 15 to 3500kVA
Production Capacity: 300pieces/Month

Phase number: three phases

Descrição

Descrição do produto

Large Capacity 15kv to 3000kVA Compact Transformer Substation Pad Mounted Transformer

The shell design adopts advanced technology, featuring solidity, thermal insulation, corrosion resistance, dustproof, waterproof, and other characteristics. Various shell materials such as aluminum alloy plate, steel plate, composite plate, stainless steel plate, and non-metallic materials are available for selection.The high-voltage switchgear options for incoming, metering, and outgoing lines include XGN15, HXGN17, or KYN28A. For low-voltage switchgear, options such as GGD, GCS, or MNS are chosen for low-voltage incoming lines, reactive power compensation, and low-voltage outgoing lines.

 

Nome Unidade Parâmetros técnicos
Tensão nominal kV 10/0.4(Medium/Low)
Maximum operating kV 12(Medium/Low)
Frequência nominal Hz 50
Rated capacity kVA 50-4000
1 minute power frequency withstand voltage kV 35
Lightning impulse voltage kV 75
Cooling method ONAN
High-voltage fuse breaking current reserve kA 50
Plug-in fuse breaking current kA 2.5
Temperatura ambiente ºC -35~+40
Coil allowable temperature rise ºC 65
No-load voltage regulation ±5%or±2*2.5%
Noise level db 50
Protection class IP43

 

CONDIÇÕES DE TRABALHO

1、Altitude: Not exceeding 2000 meters.

2、Ambient temperature:

High temperature: +40ºC; Low temperature: -45ºC; High monthly average temperature: +30ºC; High annual average     temperature: +20ºC.

3、Installation environment: No explosive, corrosive liquids, gases, or dust. The installation site should be free from severe vibrations and allows operation submerged in water for a certain period or completely.

4、Ground acceleration induced by earthquake (Ag):

Horizontal direction lower than 3m/s; Vertical direction lower than 1.5m/s.

5、Power supply voltage waveform: Approximately sinusoidal.

6、Three-phase power supply symmetry:

For three-phase underground transformers, the three-phase power supply voltage should be roughly symmetrical.

Avaliações

Ainda não existem avaliações.

Seja o primeiro a avaliar “Pad Mounted Transformer Compact Substation”

O seu endereço de email não será publicado. Campos obrigatórios marcados com *

Descarregar
Descrição do produto Large Capacity 15kv to 3000kVA Compact Transformer Substation Pad Mounted Transformer The shell design adopts advanced technology, featuring solidity, thermal insulation, corrosion resistance, dustproof, waterproof, and other characteristics. Various shell materials such as aluminum alloy plate, steel plate, composite plate, stainless steel plate, and non-metallic materials are available for selection.The high-voltage switchgear options for incoming, metering, and outgoing lines include XGN15, HXGN17, or KYN28A. For low-voltage switchgear, options such as GGD, GCS, or MNS are chosen for low-voltage incoming lines, reactive power compensation, and low-voltage outgoing lines.  
Nome Unidade Parâmetros técnicos
Tensão nominal kV 10/0.4(Medium/Low)
Maximum operating kV 12(Medium/Low)
Frequência nominal Hz 50
Rated capacity kVA 50-4000
1 minute power frequency withstand voltage kV 35
Lightning impulse voltage kV 75
Cooling method ONAN
High-voltage fuse breaking current reserve kA 50
Plug-in fuse breaking current kA 2.5
Temperatura ambiente ºC -35~+40
Coil allowable temperature rise ºC 65
No-load voltage regulation ±5%or±2*2.5%
Noise level db 50
Protection class IP43
 
CONDIÇÕES DE TRABALHO 1、Altitude: Not exceeding 2000 meters. 2、Ambient temperature: High temperature: +40ºC; Low temperature: -45ºC; High monthly average temperature: +30ºC; High annual average     temperature: +20ºC. 3、Installation environment: No explosive, corrosive liquids, gases, or dust. The installation site should be free from severe vibrations and allows operation submerged in water for a certain period or completely. 4、Ground acceleration induced by earthquake (Ag): Horizontal direction lower than 3m/s; Vertical direction lower than 1.5m/s. 5、Power supply voltage waveform: Approximately sinusoidal. 6、Three-phase power supply symmetry: For three-phase underground transformers, the three-phase power supply voltage should be roughly symmetrical.