Ligue-nos 24/7

+86 13353340627

Enviar-nos correio

info@kunji-electric.com

A nossa localização

Cidade de Wenzhou, Província de Zhejiang, China

Subestação exterior pré-instalada do tipo placa de aço

Type:       Power

Structure:       Protection

Form:      Partly-welded Type

Operation Voltage:      High Voltage

Size:      3 Uint

Application Range:      Power Plants

Descrição

Descrição do produto

 

Parâmetros técnicos

High voltage chamber Description Unidade Arguments
Frequência nominal HZ 50
Nominal voltage KV 6 10 35
Maximum operating voltage KV 6.9 12 40.5
Corrente nominal A 400,630,1250
Transfer current A 1200-2000
Rated short time current KA 12.5(2s/4s),16(2s/4s),20(2s/4s)
Rated peak tolerable current KA 31.5,40,50
Power frequency withstand voltage – to ground and time/isolation fracture KV 32/36 42/48 95/118
Lightning Strike – to ground and time/isolation fracture KV 60/70 75/85 185/215
Rated short-circuit breaking current (current limiting fuse) KA 31.5
Switch off no-load transformer capacity KVA 2500
Transformador Rated capacity KVA 30-2500
 Tap range
% ±2*2.5%,±5%
Linkage group Yyn0,Dyn11
Impedance voltage % 4,4.5,6,8
Nominal voltage V 220,380,690,800
              Low voltage chamber Rated current of main loop A 50-4000
Branch current A 5-800
The main circuit is rated to withstand short-time current KA 15(1s),30(1s),50(1s),65(1s)
Rated peak tolerable current of main loop KA 30,63,110
shell Protection class (conventional products) IP33
Noise level dB ≤50
Enclosure temperature rise level 10K

Steel Plate Type Outdoor Pre-Installed SubstationCONDIÇÕES DE TRABALHO

1. Altitude: no more than 2000M.

2. Temperatura ambiente: alta temperatura: +40ºC; Temperatura baixa: -45ºC : temperatura média mensal alta: +30ºC : temperatura média anual elevada: +20ºC;

3. installation environment: no explosive, corrosive liquid, gas and dust, installation site without violent shock, allowed in a certain period of time Or run completely submerged in water.

4. Aceleração do solo induzida pelo sismo Ag; A direção horizontal é inferior a 3m/s; A direção vertical é inferior a 1,5m/s.

5.the waveform of the power supply voltage: approximately sine wave.

6.three-phase power supply symmetry: for three-phase underground transformer, three-phase power supply voltage should be roughly symmetrical.

 

PORMENORES DE PRODUÇÃO

Steel Plate Type Outdoor Pre-Installed SubstationSteel Plate Type Outdoor Pre-Installed Substation
Steel Plate Type Outdoor Pre-Installed Substation
Steel Plate Type Outdoor Pre-Installed Substation

Avaliações

Ainda não existem avaliações.

Seja o primeiro a avaliar “Steel Plate Type Outdoor Pre-Installed Substation”

O seu endereço de email não será publicado. Campos obrigatórios marcados com *

Descrição do produto   Parâmetros técnicos
High voltage chamber Description Unidade Arguments
Frequência nominal HZ 50
Nominal voltage KV 6 10 35
Maximum operating voltage KV 6.9 12 40.5
Corrente nominal A 400,630,1250
Transfer current A 1200-2000
Rated short time current KA 12.5(2s/4s),16(2s/4s),20(2s/4s)
Rated peak tolerable current KA 31.5,40,50
Power frequency withstand voltage – to ground and time/isolation fracture KV 32/36 42/48 95/118
Lightning Strike – to ground and time/isolation fracture KV 60/70 75/85 185/215
Rated short-circuit breaking current (current limiting fuse) KA 31.5
Switch off no-load transformer capacity KVA 2500
Transformador Rated capacity KVA 30-2500
 Tap range
% ±2*2.5%,±5%
Linkage group Yyn0,Dyn11
Impedance voltage % 4,4.5,6,8
Nominal voltage V 220,380,690,800
              Low voltage chamber Rated current of main loop A 50-4000
Branch current A 5-800
The main circuit is rated to withstand short-time current KA 15(1s),30(1s),50(1s),65(1s)
Rated peak tolerable current of main loop KA 30,63,110
shell Protection class (conventional products) IP33
Noise level dB ≤50
Enclosure temperature rise level 10K
Steel Plate Type Outdoor Pre-Installed SubstationCONDIÇÕES DE TRABALHO 1. Altitude: no more than 2000M. 2. Ambient temperature: high temperature: +40ºC; Low temperature: -45ºC : high monthly average temperature: +30ºC : high annual average temperature: +20ºC; 3. installation environment: no explosive, corrosive liquid, gas and dust, installation site without violent shock, allowed in a certain period of time Or run completely submerged in water. 4. Ground acceleration induced by earthquake Ag; The horizontal direction is lower than 3m/s; The vertical direction is lower than 1.5m/s. 5.the waveform of the power supply voltage: approximately sine wave. 6.three-phase power supply symmetry: for three-phase underground transformer, three-phase power supply voltage should be roughly symmetrical.  
PORMENORES DE PRODUÇÃO Steel Plate Type Outdoor Pre-Installed SubstationSteel Plate Type Outdoor Pre-Installed Substation Steel Plate Type Outdoor Pre-Installed Substation Steel Plate Type Outdoor Pre-Installed Substation