Ligue-nos 24/7

+86 13353340627

Enviar-nos correio

info@kunji-electric.com

A nossa localização

Cidade de Wenzhou, Província de Zhejiang, China

Transformador de corrente

Descrição

Descrição do produto

 LMZJ1-0.5 series current transformer/ 0.5kv current transformer/ Low Voltage Transformers for rated frequency of 50Hz or 6OHz, rated voltage of 0.5kV and below the power system for power measurement, current measurement and relay protection.

Type designation

Parâmetros técnicos

Modelo Rated primary current(A) Rated secondary current(A) Primary

ampere-turn

Ratdlad

cosφ=0.8(VA)

Primary current required by multi-turn winding(A)
Class 0.5 Class 1 Class 3
LMZ1-0.5 5,10,20,50,100,15,30

75,150,400,200,300,400

5 100,150,200,

300,400

5 7.5 5-50 15-75 40
LMZJ1-0.5 5,10,20,30,50,700,100,150

300,400,200,400,500,600,800

5 300,400,

500-800

10 15 5-50 15-75 40
1000.1200,1500,2000,3000 5 1000-3000 30 30 50 5-50 15-75 40

CONDIÇÕES DE TRABALHO
1 The altitude is not more than 1000 meters;
2 The ambient temperature shall not be higher than +40 º C and not lower than -5 º C
3 The relative humidity of the surrounding air is not more than 85%(20 degrees);
4 The installation place is free from gas, vapor, chemical deposition, pollution, and other explosive and corrosive media that seriously affect the insulation of the transformer.

Avaliações

Ainda não existem avaliações.

Seja o primeiro a avaliar “Current Transformer”

O seu endereço de email não será publicado. Campos obrigatórios marcados com *

Descarregar
Descrição do produto  LMZJ1-0.5 series current transformer/ 0.5kv current transformer/ Low Voltage Transformers for rated frequency of 50Hz or 6OHz, rated voltage of 0.5kV and below the power system for power measurement, current measurement and relay protection. Type designation Parâmetros técnicos
Modelo Rated primary current(A) Rated secondary current(A) Primary ampere-turn Ratdlad cosφ=0.8(VA) Primary current required by multi-turn winding(A)
Class 0.5 Class 1 Class 3
LMZ1-0.5 5,10,20,50,100,15,30 75,150,400,200,300,400 5 100,150,200, 300,400 5 7.5 5-50 15-75 40
LMZJ1-0.5 5,10,20,30,50,700,100,150 300,400,200,400,500,600,800 5 300,400, 500-800 10 15 5-50 15-75 40
1000.1200,1500,2000,3000 5 1000-3000 30 30 50 5-50 15-75 40
CONDIÇÕES DE TRABALHO 1 The altitude is not more than 1000 meters; 2 The ambient temperature shall not be higher than +40 º C and not lower than -5 º C 3 The relative humidity of the surrounding air is not more than 85%(20 degrees); 4 The installation place is free from gas, vapor, chemical deposition, pollution, and other explosive and corrosive media that seriously affect the insulation of the transformer.