Bel ons 24/7

+86 13353340627

Stuur ons e-mail

info@kunji-electric.com

Onze locatie

Wenzhou, provincie Zhejiang, China

MNS-serie schakelapparatuur

Certificering: CCC, ISO9001

Shell Material:Steel Plate

Installation:Fixed

Structure:Withdrawable

Beschrijving

Overzicht

The MNS series distribution cabinet, renowned for its reliability, is a modular, multifunctional low-voltage solution tailored for industrial applications. Capable of supporting systems up to 4000A, it provides robust protection for both personnel and equipment safety, thanks to its flexible cabinet structure and humanized design.

 

Soorten betekenissen

 

Productparameters

Number GB7251.1-2005 Low-voltage switchgear and control equipment (T TA)

EC60439 《Low-voltage switchgear and control equipment》

1 Overvoltage category IV III
2 pollution level 3
3 Rated working voltage (Ue) (V) Rated working voltage (Ue) (V) 400/660
4 Rated insulation voltage (Ui) (V) Rated insulation voltage (Ui) (V) 660/1000
5 Rated frequency(Hz) Rated frequency(Hz) 50(60)
6 horizontal bus Nominale stroom ≤5000A
7 Rated short-time withstand current (lcw) (kA) 50,65,80(1s valid value)
8 Rated peak withstand current (pk) (kA) 105,140,176(0.1s maximum value)
9 vertical bus Rated maximum working current ≤1000A
10 Rated short-time withstand current (lcw) (kA) 50kA
11 Nominale piekweerstandsstroom 105kA
12 Enclosure rating IP30 IP40(Special Instructions)

 

Product Maat Beschrijving

 

Arbeidsomstandigheden

Here is the English description regarding the application, implementation standards, environmental conditions, installation site, and altitude for power distribution and motor control:

1. Application:Power distribution, motor control.
2. Implementation standards:IEC439, GB7251.1.
3. Environmental conditions:Operating temperature range: -5 ℃ to 40 ℃. At 40 ℃, the relative humidity should not exceed 50%. At lower temperatures, higher relative humidity is permitted, and occasional condensation may occur (e.g., 90% at 20 ℃).
4. Installation site:Indoor.
5. Altitude:≤ 2000 meters.
Note: If unable to meet the above conditions, users should communicate their requirements to the manufacturer at the time of ordering.

Beoordelingen

Er zijn nog geen beoordelingen.

Wees de eerste om “MNS Series Switchgear” te beoordelen

Het e-mailadres wordt niet gepubliceerd. Vereiste velden zijn gemarkeerd met *

Downloaden
Overzicht The MNS series distribution cabinet, renowned for its reliability, is a modular, multifunctional low-voltage solution tailored for industrial applications. Capable of supporting systems up to 4000A, it provides robust protection for both personnel and equipment safety, thanks to its flexible cabinet structure and humanized design.   Soorten betekenissen   Productparameters
Number GB7251.1-2005 Low-voltage switchgear and control equipment (T TA) EC60439 《Low-voltage switchgear and control equipment》
1 Overvoltage category IV III
2 pollution level 3
3 Rated working voltage (Ue) (V) Rated working voltage (Ue) (V) 400/660
4 Rated insulation voltage (Ui) (V) Rated insulation voltage (Ui) (V) 660/1000
5 Rated frequency(Hz) Rated frequency(Hz) 50(60)
6 horizontal bus Nominale stroom ≤5000A
7 Rated short-time withstand current (lcw) (kA) 50,65,80(1s valid value)
8 Rated peak withstand current (pk) (kA) 105,140,176(0.1s maximum value)
9 vertical bus Rated maximum working current ≤1000A
10 Rated short-time withstand current (lcw) (kA) 50kA
11 Nominale piekweerstandsstroom 105kA
12 Enclosure rating IP30 IP40(Special Instructions)
  Product Maat Beschrijving   Arbeidsomstandigheden Here is the English description regarding the application, implementation standards, environmental conditions, installation site, and altitude for power distribution and motor control: 1. Application:Power distribution, motor control. 2. Implementation standards:IEC439, GB7251.1. 3. Environmental conditions:Operating temperature range: -5 ℃ to 40 ℃. At 40 ℃, the relative humidity should not exceed 50%. At lower temperatures, higher relative humidity is permitted, and occasional condensation may occur (e.g., 90% at 20 ℃). 4. Installation site:Indoor. 5. Altitude:≤ 2000 meters. Note: If unable to meet the above conditions, users should communicate their requirements to the manufacturer at the time of ordering.