SPD/AC雷サージプロテクター

Type: Power Source Arrester
Structure: Protective Gap
Installation: Parallel Arrester
Application: AC/DC System
Size: Small
Operation Voltage: Low Voltage

説明

商品説明

An AC Lightning Surge Protector (SPD) safeguards sensitive electronic equipment from voltage spikes caused by lightning strikes or electrical disturbances. It’s vital for protecting devices like computers, TVs, and safety circuits, ensuring their smooth operation during electrical disturbances.

 

技術パラメーター

T2-20/2P
T2-20/2PF
T2-20/3P
T2-20/3PF
T2-20/4P
T2-20/4PF
T2-20/1P+1
T2-20/1P+1F
T2-20/3P+1
T2-20/3P+1F
Max. continuous operating voltage Uc 320VAC 320VAC 320VAC 320VAC 320VAC
Nominal discharge current In(8/20µs) 10kA 10kA 10kA 10kA 10kA
Max. discharge current Imax(8/20µs) 20kA 20kA 20kA 20kA 20kA
Voltage protection level Up 1.2kV 1.2kV 1.2kV 1.2kV 1.2kV
Recommended backup fuse 40A gG 40A gG 40A gG 40A gG 40A gG
Recommended grounding cable 4~35mm2 4~35mm2 4~35mm2 4~35mm2 4~35mm2
Response time 25ns 25ns 25ns 25ns 25ns
Residual current IPE <10μA <10μA <10μA <10μA <10μA
Remote alarm output 250VAC/0.5A;24VDC/0.5A 250VAC/0.5A;24VDC/0.5A 250VAC/0.5A;24VDC/0.5A 250VAC/0.5A;24VDC/0.5A 250VAC/0.5A;24VDC/0.5A
Housing protection grade(IEC60529) IP 20 IP 20 IP 20 IP 20 IP 20
Housing material/inflammability rating(UL94) PA66/V0 PA66/V0 PA66/V0 PA66/V0 PA66/V0
Testing standard IEC 61643-11 IEC 61643-11 IEC 61643-11 IEC 61643-11 IEC 61643-11
Suitable for power supply system TN system(single phase) IT,TN-C system(three phase) TN-S system(three phase) IT,TN-C system(single phase) TT system(three phase)

労働条件

1. Altitude: ≤ 2,000 meters.
2. Temperature: The range is -5 ~ 40°C, with a limit range of -40 ~ 70°C.
3. Relative Humidity: Should be maintained between 30% ~ 90% at room temperature.
4. Special considerations are required in the design and use, paying attention to special circumstances under abnormal service conditions.

AC Lightning Surge Protector /SPDAC Lightning Surge Protector /SPDAC Lightning Surge Protector /SPD

 

レビュー

レビューはまだありません。

“SPD/AC Lightning Surge Protector” の口コミを投稿します

メールアドレスが公開されることはありません。 が付いている欄は必須項目です

ダウンロード
商品説明 An AC Lightning Surge Protector (SPD) safeguards sensitive electronic equipment from voltage spikes caused by lightning strikes or electrical disturbances. It’s vital for protecting devices like computers, TVs, and safety circuits, ensuring their smooth operation during electrical disturbances.   技術パラメーター
T2-20/2P T2-20/2PF T2-20/3P T2-20/3PF T2-20/4P T2-20/4PF T2-20/1P+1 T2-20/1P+1F T2-20/3P+1 T2-20/3P+1F
Max. continuous operating voltage Uc 320VAC 320VAC 320VAC 320VAC 320VAC
Nominal discharge current In(8/20µs) 10kA 10kA 10kA 10kA 10kA
Max. discharge current Imax(8/20µs) 20kA 20kA 20kA 20kA 20kA
Voltage protection level Up 1.2kV 1.2kV 1.2kV 1.2kV 1.2kV
Recommended backup fuse 40A gG 40A gG 40A gG 40A gG 40A gG
Recommended grounding cable 4~35mm2 4~35mm2 4~35mm2 4~35mm2 4~35mm2
Response time 25ns 25ns 25ns 25ns 25ns
Residual current IPE <10μA <10μA <10μA <10μA <10μA
Remote alarm output 250VAC/0.5A;24VDC/0.5A 250VAC/0.5A;24VDC/0.5A 250VAC/0.5A;24VDC/0.5A 250VAC/0.5A;24VDC/0.5A 250VAC/0.5A;24VDC/0.5A
Housing protection grade(IEC60529) IP 20 IP 20 IP 20 IP 20 IP 20
Housing material/inflammability rating(UL94) PA66/V0 PA66/V0 PA66/V0 PA66/V0 PA66/V0
Testing standard IEC 61643-11 IEC 61643-11 IEC 61643-11 IEC 61643-11 IEC 61643-11
Suitable for power supply system TN system(single phase) IT,TN-C system(three phase) TN-S system(three phase) IT,TN-C system(single phase) TT system(three phase)
労働条件
1. Altitude: ≤ 2,000 meters. 2. Temperature: The range is -5 ~ 40°C, with a limit range of -40 ~ 70°C. 3. Relative Humidity: Should be maintained between 30% ~ 90% at room temperature. 4. Special considerations are required in the design and use, paying attention to special circumstances under abnormal service conditions.