屋外用複合ボード小型変圧器

Type:Kiosk Substation

Rated Voltage: 4-24 Kv

Certification:ISO9001:2000, CCC

Rated Capacity: 50 to 3500kVA

Production Capacity: 100pieces/Month

説明

商品説明

Yb Series 10kv 200kVA~2000kVA Outdoor Compact Transformer Substation European Style Substation 

技術パラメーター

High voltage chamber Description 単位 Arguments
定格周波数 HZ 50
Nominal voltage KV 6 10 35
Maximum operating voltage KV 6.9 12 40.5
定格電流 A 400,630,1250
Transfer current A 1200-2000
Rated short time current KA 12.5(2s/4s),16(2s/4s),20(2s/4s)
Rated peak tolerable current KA 31.5,40,50
Power frequency withstand voltage – to ground and time/isolation fracture KV 32/36 42/48 95/118
Lightning Strike – to ground and time/isolation fracture KV 60/70 75/85 185/215
Rated short-circuit breaking current (current limiting fuse) KA 31.5
Switch off no-load transformer capacity KVA 2500
変圧器 Rated capacity KVA 30-2500
 Tap range
% ±2*2.5%,±5%
Linkage group Yyn0,Dyn11
Impedance voltage % 4,4.5,6,8
Nominal voltage V 220,380,690,800
              Low voltage chamber Rated current of main loop A 50-4000
Branch current A 5-800
The main circuit is rated to withstand short-time current KA 15(1s),30(1s),50(1s),65(1s)
Rated peak tolerable current of main loop KA 30,63,110
shell Protection class (conventional products) IP33
Noise level dB ≤50
Enclosure temperature rise level 10K

Yb Series 10kv 200kVA~2000kVA Outdoor Compact Transformer Substation European Style Substation

労働条件

1. Altitude: no more than 2000M.

 

2. Ambient temperature: high temperature: +40ºC; Low temperature: -45ºC : high monthly average temperature: +30ºC : high annual average temperature: +20ºC;

 

3, installation environment: no explosive, corrosive liquid, gas and dust, installation site without violent shock, allowed in a certain period of time Or run completely submerged in water.

 

4. Ground acceleration induced by earthquake Ag; The horizontal direction is lower than 3m/s; The vertical direction is lower than 1.5m/s.

 

5, the waveform of the power supply voltage: approximately sine wave.

 

6, three-phase power supply symmetry: for three-phase underground transformer, three-phase power supply voltage should be roughly symmetrical.

プロダクション詳細

Complete transformer substation
Outdoor Compact Transformer
Complete transformer substation
Outdoor Compact Transformer
Complete transformer substation
Outdoor Compact Transformer

レビュー

レビューはまだありません。

“Outdoor Composite Board Compact Transformer” の口コミを投稿します

メールアドレスが公開されることはありません。 が付いている欄は必須項目です

ダウンロード
商品説明 Yb Series 10kv 200kVA~2000kVA Outdoor Compact Transformer Substation European Style Substation 
技術パラメーター
High voltage chamber Description 単位 Arguments
定格周波数 HZ 50
Nominal voltage KV 6 10 35
Maximum operating voltage KV 6.9 12 40.5
定格電流 A 400,630,1250
Transfer current A 1200-2000
Rated short time current KA 12.5(2s/4s),16(2s/4s),20(2s/4s)
Rated peak tolerable current KA 31.5,40,50
Power frequency withstand voltage – to ground and time/isolation fracture KV 32/36 42/48 95/118
Lightning Strike – to ground and time/isolation fracture KV 60/70 75/85 185/215
Rated short-circuit breaking current (current limiting fuse) KA 31.5
Switch off no-load transformer capacity KVA 2500
変圧器 Rated capacity KVA 30-2500
 Tap range
% ±2*2.5%,±5%
Linkage group Yyn0,Dyn11
Impedance voltage % 4,4.5,6,8
Nominal voltage V 220,380,690,800
              Low voltage chamber Rated current of main loop A 50-4000
Branch current A 5-800
The main circuit is rated to withstand short-time current KA 15(1s),30(1s),50(1s),65(1s)
Rated peak tolerable current of main loop KA 30,63,110
shell Protection class (conventional products) IP33
Noise level dB ≤50
Enclosure temperature rise level 10K
Yb Series 10kv 200kVA~2000kVA Outdoor Compact Transformer Substation European Style Substation 労働条件 1. Altitude: no more than 2000M.   2. Ambient temperature: high temperature: +40ºC; Low temperature: -45ºC : high monthly average temperature: +30ºC : high annual average temperature: +20ºC;   3, installation environment: no explosive, corrosive liquid, gas and dust, installation site without violent shock, allowed in a certain period of time Or run completely submerged in water.   4. Ground acceleration induced by earthquake Ag; The horizontal direction is lower than 3m/s; The vertical direction is lower than 1.5m/s.   5, the waveform of the power supply voltage: approximately sine wave.   6, three-phase power supply symmetry: for three-phase underground transformer, three-phase power supply voltage should be roughly symmetrical.
プロダクション詳細
Complete transformer substation
Outdoor Compact Transformer