Transformateur de type standard américain

Shell Material: Steel Plate
Rated Voltage: 4-24 Kv
Certification: ISO9001:2000, CCC,CE
Form: Partly-welded Type
Rated Capacity: 50 to 3500kVA
Production Capacity: 300pieces/Month

Phase number: three phases

Description

Description du produit

Pad Mounted (American type) Transformer 100 to 3000kVA Oil Immersed Prefabricated Substation 

Outdoor prefabricated transformer substation. EU or US style. 12kV, 15kV, 24kV, 36kV. Available.
MV RMU equiped, LV can be optional with reactive power compensator or with Harmonic wave filtering.
Outdoor prefabricated transformer substation(Combined Transformer)
Paramètres techniques

Nom  Unité   MV equipment   Transformateur  LV Equipment
 Tension nominale  kV  11~33kV  11~33kV/0.4  0.4
 Courant nominal  A   630  3/75~150/3750 Less than 4000
 Frequency  Hz    50
 Rated Capacity  kVA  50-2500
 Pfr withstand   kV  42/50/70/95  2.5
  BIL  kV   75/125/170/185
Crust Protection Grade  IP23 Oil type 55; dry type 65 IP23
Noisy Grade  dB
Appearance Dimensions mm According to primacy wiring circuit schema

LES CONDITIONS DE TRAVAIL
1. Altitude : pas plus de 2000 m.

 

2. Température ambiante : température élevée : +40ºC ; température basse : -45ºC : température moyenne mensuelle élevée : +30ºC : température moyenne annuelle élevée : +20ºC ;

 

3, environnement d'installation : pas de liquide explosif, corrosif, de gaz et de poussière, site d'installation sans choc violent, autorisé dans un certain laps de temps. Ou courir complètement immergé dans l'eau.

 

4. Accélération du sol induite par le tremblement de terre Ag ; La direction horizontale est inférieure à 3m/s ; La direction verticale est inférieure à 1,5m/s.

 

5, la forme d'onde de la tension d'alimentation : approximativement sinusoïdale.

 

6, symétrie de l'alimentation triphasée : pour les transformateurs souterrains triphasés, la tension d'alimentation triphasée doit être à peu près symétrique.

DÉTAILS DE LA PRODUCTION
Pad Mounted (American type) Transformer 100 to 3000kVA Oil Immersed Prefabricated SubstationPad Mounted (American type) Transformer 100 to 3000kVA Oil Immersed Prefabricated Substation

Avis

Il n’y a pas encore d’avis.

Soyez le premier à laisser votre avis sur “American standard Type Transformer”

Votre adresse e-mail ne sera pas publiée. Les champs obligatoires sont indiqués avec *

Télécharger
Description du produit Pad Mounted (American type) Transformer 100 to 3000kVA Oil Immersed Prefabricated Substation  Outdoor prefabricated transformer substation. EU or US style. 12kV, 15kV, 24kV, 36kV. Available. MV RMU equiped, LV can be optional with reactive power compensator or with Harmonic wave filtering. Outdoor prefabricated transformer substation(Combined Transformer) Paramètres techniques
Nom  Unité   MV equipment   Transformateur  LV Equipment
 Tension nominale  kV  11~33kV  11~33kV/0.4  0.4
 Courant nominal  A   630  3/75~150/3750 Less than 4000
 Frequency  Hz    50
 Rated Capacity  kVA  50-2500
 Pfr withstand   kV  42/50/70/95  2.5
  BIL  kV   75/125/170/185
Crust Protection Grade  IP23 Oil type 55; dry type 65 IP23
Noisy Grade  dB
Appearance Dimensions mm According to primacy wiring circuit schema
LES CONDITIONS DE TRAVAIL 1. Altitude : pas plus de 2000 m.   2. Température ambiante : température élevée : +40ºC ; température basse : -45ºC : température moyenne mensuelle élevée : +30ºC : température moyenne annuelle élevée : +20ºC ;   3, environnement d'installation : pas de liquide explosif, corrosif, de gaz et de poussière, site d'installation sans choc violent, autorisé dans un certain laps de temps. Ou courir complètement immergé dans l'eau.   4. Accélération du sol induite par le tremblement de terre Ag ; La direction horizontale est inférieure à 3m/s ; La direction verticale est inférieure à 1,5m/s.   5, la forme d'onde de la tension d'alimentation : approximativement sinusoïdale.   6, symétrie de l'alimentation triphasée : pour les transformateurs souterrains triphasés, la tension d'alimentation triphasée doit être à peu près symétrique. DÉTAILS DE LA PRODUCTION Pad Mounted (American type) Transformer 100 to 3000kVA Oil Immersed Prefabricated SubstationPad Mounted (American type) Transformer 100 to 3000kVA Oil Immersed Prefabricated Substation