Appelez-nous 24 heures sur 24, 7 jours sur 7

+86 13353340627

Envoyez-nous un courrier

info@kunji-electric.com

Notre emplacement

Ville de Wenzhou, province de Zhejiang, Chine

Série parafoudre basse tension Polymère

Application: Insulators, Electrical Winding Insulation, Winding Wire Coating Insulation, Electrical Base, Shell, Switch Baseplate
Type: Insulation Tape
Chemistry: Organic Insulation
Material: Rubber
Thermal Rating: 220 220
Maximum Voltage: <10KV

Description

Description du produit

 Low Voltage Surge Lightning Arrester  Parameters

el System Rated voltage Arrester rated voltage MCOV DC U1mA 8/20us ligntninh impulse residual voltage 2ms rectangular wave allowed current capacity 4,10us high current impulse withstand
                      kV(r.m.s) ≮kV ≯kV
HY5WS-3.8/15    3 3.8 2 7.5 15 75A 40kA
HY5WS-5/15 5 4 8 15 90A 65kA
HY5WS-7.6/30    6 7.6 4 15 30 75A 40kA
HY5WS-10/30 10 8 15 30 90A 65kA
HY5WS-12.7/50 10 12.7 6.6 25 50 75A 40kA
HY5WS-17/50 17 13.6 25 50 90A 65kA

LES CONDITIONS DE TRAVAILa) Ambient air temperature within the range of -55ºC to +50ºC.

b) Altitude not exceeding 2000m.

c) Frequency of the A.C. Power supply not less than 48Hz and not exceeding 62Hz.

d) Power frequency voltage applied continuously between the terminals of the arrester not exceeding its continuous operating voltage.

e) Maximum wind speed not exceeding 35m/s.

f) Earthquake intensity not exceeding 7 degrees.

DÉTAILS DE LA PRODUCTION

Low Voltage Surge Lightning Arrester Metal Oxide Gapless ZnO Polymeric Type 500V

Avis

Il n’y a pas encore d’avis.

Soyez le premier à laisser votre avis sur “Low Voltage Arrester Series Polymeric”

Votre adresse e-mail ne sera pas publiée. Les champs obligatoires sont indiqués avec *

Télécharger

Description du produit

 Low Voltage Surge Lightning Arrester  Parameters
el System Rated voltage Arrester rated voltage MCOV DC U1mA 8/20us ligntninh impulse residual voltage 2ms rectangular wave allowed current capacity 4,10us high current impulse withstand
                      kV(r.m.s) ≮kV ≯kV
HY5WS-3.8/15    3 3.8 2 7.5 15 75A 40kA
HY5WS-5/15 5 4 8 15 90A 65kA
HY5WS-7.6/30    6 7.6 4 15 30 75A 40kA
HY5WS-10/30 10 8 15 30 90A 65kA
HY5WS-12.7/50 10 12.7 6.6 25 50 75A 40kA
HY5WS-17/50 17 13.6 25 50 90A 65kA
LES CONDITIONS DE TRAVAILa) Ambient air temperature within the range of -55ºC to +50ºC. b) Altitude not exceeding 2000m. c) Frequency of the A.C. Power supply not less than 48Hz and not exceeding 62Hz. d) Power frequency voltage applied continuously between the terminals of the arrester not exceeding its continuous operating voltage. e) Maximum wind speed not exceeding 35m/s. f) Earthquake intensity not exceeding 7 degrees. DÉTAILS DE LA PRODUCTION Low Voltage Surge Lightning Arrester Metal Oxide Gapless ZnO Polymeric Type 500V