Moulded Case Circuit Breaker Three Poles 63A to 1600A

Type: Moulded Case Circuit Breaker
Material: ABS+Copper
Model NO.: KJM1-250L/3300
Poles Number: 3
Use Current: 63-1600A
Rated Voltage: 100-690V

Description

Description du produit

Molded Case Circuit Breakers are one of the primary power handling devices available in industrial environments.

Paramètres techniques

Paramètres Description
Rated Frame Current (Inm) This is the maximum current that the MCCB can handle.
This is typically the maximum value of the adjustable tripping current range.
Rated Current (In) This is the breaker tripping current.
This value is less than the rated frame current and is adjustable.
Rated Insulation Voltage (Ui) Insulation voltage is the maximum withstandable voltage that the breaker housing can handle.
This is measured under laboratory conditions.
Rated Operating Voltage (Ue) Continuous operating voltage of the MCCB.
This is the typical system voltage and can be lower.
Rated Impulse Withstand Voltage (Uimp) Rated impulse withstand voltage is the voltage that the MCCB can handle
during a surge event such as a lightning strike.
The testing is standardized for a 1.2/50 microsecond impulse.
Short Circuit Breaking Capacity (Ics) I_cs is the highest fault current an MCCB can handle without damaging the unit permanently.
The device must always be used below this limit.
Mechanical  Endurance This provides an estimation of manual on/off cycles before the mechanical lever system fails.
Electrical Endurance Electrical life provides a figure on how many times a unit can trip before it needs replacement.

LES CONDITIONS DE TRAVAIL
1 The altitude is not more than 1500 meters;
2 La température ambiante ne doit pas être supérieure à +40 º C et inférieure à -5 º C.
3 L'humidité relative de l'air ambiant n'est pas supérieure à 85%(20 degrés) ;
4 Le lieu d'installation est exempt de gaz, de vapeur, de dépôts chimiques, de pollution et d'autres milieux explosifs et corrosifs qui affectent sérieusement l'isolation du transformateur.

DÉTAILS DE LA PRODUCTION

Moulded Case Circuit Breaker
Moulded Case Circuit Breaker -Wenzhou Kunji Trading
Moulded Case Circuit Breaker
Moulded Case Circuit Breaker -Wenzhou Kunji Trading

Avis

Il n’y a pas encore d’avis.

Soyez le premier à laisser votre avis sur “Moulded Case Circuit Breaker Three Poles 63A to 1600A”

Votre adresse e-mail ne sera pas publiée. Les champs obligatoires sont indiqués avec *

Télécharger
Description du produit Molded Case Circuit Breakers are one of the primary power handling devices available in industrial environments. Paramètres techniques
Paramètres Description
Rated Frame Current (Inm) This is the maximum current that the MCCB can handle. This is typically the maximum value of the adjustable tripping current range.
Rated Current (In) This is the breaker tripping current. This value is less than the rated frame current and is adjustable.
Rated Insulation Voltage (Ui) Insulation voltage is the maximum withstandable voltage that the breaker housing can handle. This is measured under laboratory conditions.
Rated Operating Voltage (Ue) Continuous operating voltage of the MCCB. This is the typical system voltage and can be lower.
Rated Impulse Withstand Voltage (Uimp) Rated impulse withstand voltage is the voltage that the MCCB can handle during a surge event such as a lightning strike. The testing is standardized for a 1.2/50 microsecond impulse.
Short Circuit Breaking Capacity (Ics) I_cs is the highest fault current an MCCB can handle without damaging the unit permanently. The device must always be used below this limit.
Mechanical  Endurance This provides an estimation of manual on/off cycles before the mechanical lever system fails.
Electrical Endurance Electrical life provides a figure on how many times a unit can trip before it needs replacement.
LES CONDITIONS DE TRAVAIL 1 The altitude is not more than 1500 meters; 2 The ambient temperature shall not be higher than +40 º C and not lower than -5 º C 3 The relative humidity of the surrounding air is not more than 85%(20 degrees); 4 The installation place is free from gas, vapor, chemical deposition, pollution, and other explosive and corrosive media that seriously affect the insulation of the transformer. DÉTAILS DE LA PRODUCTION
Moulded Case Circuit Breaker
Moulded Case Circuit Breaker -Wenzhou Kunji Trading
Moulded Case Circuit Breaker
Moulded Case Circuit Breaker -Wenzhou Kunji Trading