Appareils de commutation de la série MNS

Certification : CCC, ISO9001

Shell Material:Steel Plate

Installation:Fixed

Structure:Withdrawable

Description

Vue d'ensemble

The MNS series distribution cabinet, renowned for its reliability, is a modular, multifunctional low-voltage solution tailored for industrial applications. Capable of supporting systems up to 4000A, it provides robust protection for both personnel and equipment safety, thanks to its flexible cabinet structure and humanized design.

 

Types de signification

 

Paramètres du produit

Number GB7251.1-2005 Low-voltage switchgear and control equipment (T TA)

EC60439 《Low-voltage switchgear and control equipment》

1 Overvoltage category IV III
2 pollution level 3
3 Rated working voltage (Ue) (V) Rated working voltage (Ue) (V) 400/660
4 Rated insulation voltage (Ui) (V) Rated insulation voltage (Ui) (V) 660/1000
5 Rated frequency(Hz) Rated frequency(Hz) 50(60)
6 horizontal bus Courant nominal ≤5000A
7 Rated short-time withstand current (lcw) (kA) 50,65,80(1s valid value)
8 Rated peak withstand current (pk) (kA) 105,140,176(0.1s maximum value)
9 vertical bus Rated maximum working current ≤1000A
10 Rated short-time withstand current (lcw) (kA) 50kA
11 Rated peak withstand current 105kA
12 Enclosure rating IP30 IP40(Special Instructions)

 

Taille du produit Description

 

Conditions de travail

Here is the English description regarding the application, implementation standards, environmental conditions, installation site, and altitude for power distribution and motor control:

1. Application:Power distribution, motor control.
2. Implementation standards:IEC439, GB7251.1.
3. Environmental conditions:Operating temperature range: -5 ℃ to 40 ℃. At 40 ℃, the relative humidity should not exceed 50%. At lower temperatures, higher relative humidity is permitted, and occasional condensation may occur (e.g., 90% at 20 ℃).
4. Installation site:Indoor.
5. Altitude:≤ 2000 meters.
Note: If unable to meet the above conditions, users should communicate their requirements to the manufacturer at the time of ordering.

Avis

Il n’y a pas encore d’avis.

Soyez le premier à laisser votre avis sur “MNS Series Switchgear”

Votre adresse e-mail ne sera pas publiée. Les champs obligatoires sont indiqués avec *

Télécharger
Vue d'ensemble The MNS series distribution cabinet, renowned for its reliability, is a modular, multifunctional low-voltage solution tailored for industrial applications. Capable of supporting systems up to 4000A, it provides robust protection for both personnel and equipment safety, thanks to its flexible cabinet structure and humanized design.   Types de signification   Paramètres du produit
Number GB7251.1-2005 Low-voltage switchgear and control equipment (T TA) EC60439 《Low-voltage switchgear and control equipment》
1 Overvoltage category IV III
2 pollution level 3
3 Rated working voltage (Ue) (V) Rated working voltage (Ue) (V) 400/660
4 Rated insulation voltage (Ui) (V) Rated insulation voltage (Ui) (V) 660/1000
5 Rated frequency(Hz) Rated frequency(Hz) 50(60)
6 horizontal bus Courant nominal ≤5000A
7 Rated short-time withstand current (lcw) (kA) 50,65,80(1s valid value)
8 Rated peak withstand current (pk) (kA) 105,140,176(0.1s maximum value)
9 vertical bus Rated maximum working current ≤1000A
10 Rated short-time withstand current (lcw) (kA) 50kA
11 Rated peak withstand current 105kA
12 Enclosure rating IP30 IP40(Special Instructions)
  Taille du produit Description   Conditions de travail Here is the English description regarding the application, implementation standards, environmental conditions, installation site, and altitude for power distribution and motor control: 1. Application:Power distribution, motor control. 2. Implementation standards:IEC439, GB7251.1. 3. Environmental conditions:Operating temperature range: -5 ℃ to 40 ℃. At 40 ℃, the relative humidity should not exceed 50%. At lower temperatures, higher relative humidity is permitted, and occasional condensation may occur (e.g., 90% at 20 ℃). 4. Installation site:Indoor. 5. Altitude:≤ 2000 meters. Note: If unable to meet the above conditions, users should communicate their requirements to the manufacturer at the time of ordering.