Certification:CCC, ISO9001

Shell Material:Steel Plate

Installation:Fixed

Structure:Withdrawable

Beschreibung

Übersicht

The MNS series distribution cabinet, renowned for its reliability, is a modular, multifunctional low-voltage solution tailored for industrial applications. Capable of supporting systems up to 4000A, it provides robust protection for both personnel and equipment safety, thanks to its flexible cabinet structure and humanized design.

 

Arten von Bedeutung

 

Produkt-Parameter

Number GB7251.1-2005 Low-voltage switchgear and control equipment (T TA)

EC60439 《Low-voltage switchgear and control equipment》

1 Overvoltage category IV III
2 pollution level 3
3 Rated working voltage (Ue) (V) Rated working voltage (Ue) (V) 400/660
4 Rated insulation voltage (Ui) (V) Rated insulation voltage (Ui) (V) 660/1000
5 Rated frequency(Hz) Rated frequency(Hz) 50(60)
6 horizontal bus Rated current ≤5000A
7 Rated short-time withstand current (lcw) (kA) 50,65,80(1s valid value)
8 Rated peak withstand current (pk) (kA) 105,140,176(0.1s maximum value)
9 vertical bus Rated maximum working current ≤1000A
10 Rated short-time withstand current (lcw) (kA) 50kA
11 Rated peak withstand current 105kA
12 Enclosure rating IP30 IP40(Special Instructions)

 

Produktgröße Beschreibung

 

Arbeitsbedingungen

Here is the English description regarding the application, implementation standards, environmental conditions, installation site, and altitude for power distribution and motor control:

1. Application:Power distribution, motor control.
2. Implementation standards:IEC439, GB7251.1.
3. Environmental conditions:Operating temperature range: -5 ℃ to 40 ℃. At 40 ℃, the relative humidity should not exceed 50%. At lower temperatures, higher relative humidity is permitted, and occasional condensation may occur (e.g., 90% at 20 ℃).
4. Installation site:Indoor.
5. Altitude:≤ 2000 meters.
Note: If unable to meet the above conditions, users should communicate their requirements to the manufacturer at the time of ordering.

Bewertungen

Es gibt noch keine Bewertungen.

Schreibe die erste Bewertung für „MNS Series Switchgear“

Deine E-Mail-Adresse wird nicht veröffentlicht. Erforderliche Felder sind mit * markiert

Herunterladen
Übersicht The MNS series distribution cabinet, renowned for its reliability, is a modular, multifunctional low-voltage solution tailored for industrial applications. Capable of supporting systems up to 4000A, it provides robust protection for both personnel and equipment safety, thanks to its flexible cabinet structure and humanized design.   Arten von Bedeutung   Produkt-Parameter
Number GB7251.1-2005 Low-voltage switchgear and control equipment (T TA) EC60439 《Low-voltage switchgear and control equipment》
1 Overvoltage category IV III
2 pollution level 3
3 Rated working voltage (Ue) (V) Rated working voltage (Ue) (V) 400/660
4 Rated insulation voltage (Ui) (V) Rated insulation voltage (Ui) (V) 660/1000
5 Rated frequency(Hz) Rated frequency(Hz) 50(60)
6 horizontal bus Rated current ≤5000A
7 Rated short-time withstand current (lcw) (kA) 50,65,80(1s valid value)
8 Rated peak withstand current (pk) (kA) 105,140,176(0.1s maximum value)
9 vertical bus Rated maximum working current ≤1000A
10 Rated short-time withstand current (lcw) (kA) 50kA
11 Rated peak withstand current 105kA
12 Enclosure rating IP30 IP40(Special Instructions)
  Produktgröße Beschreibung   Arbeitsbedingungen Here is the English description regarding the application, implementation standards, environmental conditions, installation site, and altitude for power distribution and motor control: 1. Application:Power distribution, motor control. 2. Implementation standards:IEC439, GB7251.1. 3. Environmental conditions:Operating temperature range: -5 ℃ to 40 ℃. At 40 ℃, the relative humidity should not exceed 50%. At lower temperatures, higher relative humidity is permitted, and occasional condensation may occur (e.g., 90% at 20 ℃). 4. Installation site:Indoor. 5. Altitude:≤ 2000 meters. Note: If unable to meet the above conditions, users should communicate their requirements to the manufacturer at the time of ordering.