Three-Phase MCB 16-63A Miniature Circuit Breakers

Type: Fuse Miniature Circuit Breakers
Material: ABS+Copper
Model NO.: DZ47-32
Poles Number: 3
Use Current: 6-63A
Rated Voltage: 100-690V

Beschreibung

Beschreibung des Produkts

Miniature Circuit Breakers (MCBs) are primarily found in domestic power distribution boards to control electrical power applied to different circuits within a premise.

Technische Parameter

1. Rated Voltage: Usually 230V, 400V, or other specific voltage levels.
2. Rated Current: Typically measured in Amperes (A), representing the circuit breaker’s rated load capacity. Common rated currents include 6A, 10A, 16A, 20A, 32A, etc.
3. Breaking Capacity: Also known as short-circuit capacity, it indicates the maximum fault current that the circuit breaker can safely interrupt. Common breaking capacities include 6000A, 10000A, etc.
4. Poles: Refers to the number of poles of the circuit breaker, which can be single-pole, double-pole, triple-pole, or four-pole.
5. Tripping Method: Typically includes overload protection, short-circuit protection, and ground fault protection, among others.

ARBEITSBEDINGUNGEN
1 .The altitude is not more than 1000 meters;
2 .The ambient temperature shall not be higher than +40 º C and not lower than -5 º C
3 .The relative humidity of the surrounding air is not more than 85%(20 degrees);
4 .The installation place is free from gas, vapor, chemical deposition, pollution, and other explosive and corrosive media that seriously affect the insulation of the transformer.

PRODUKTIONSDETAILS

Miniature Circuit Breakers
Miniature Circuit Breakers-Wenzhou Kunji Trading

Bewertungen

Es gibt noch keine Bewertungen.

Schreibe die erste Bewertung für „Three-Phase MCB 16-63A Miniature Circuit Breakers“

Deine E-Mail-Adresse wird nicht veröffentlicht. Erforderliche Felder sind mit * markiert

Herunterladen
Beschreibung des Produkts Miniature Circuit Breakers (MCBs) are primarily found in domestic power distribution boards to control electrical power applied to different circuits within a premise. Technische Parameter
1. Rated Voltage: Usually 230V, 400V, or other specific voltage levels. 2. Rated Current: Typically measured in Amperes (A), representing the circuit breaker’s rated load capacity. Common rated currents include 6A, 10A, 16A, 20A, 32A, etc. 3. Breaking Capacity: Also known as short-circuit capacity, it indicates the maximum fault current that the circuit breaker can safely interrupt. Common breaking capacities include 6000A, 10000A, etc. 4. Poles: Refers to the number of poles of the circuit breaker, which can be single-pole, double-pole, triple-pole, or four-pole. 5. Tripping Method: Typically includes overload protection, short-circuit protection, and ground fault protection, among others.
ARBEITSBEDINGUNGEN 1 .The altitude is not more than 1000 meters; 2 .The ambient temperature shall not be higher than +40 º C and not lower than -5 º C 3 .The relative humidity of the surrounding air is not more than 85%(20 degrees); 4 .The installation place is free from gas, vapor, chemical deposition, pollution, and other explosive and corrosive media that seriously affect the insulation of the transformer. PRODUKTIONSDETAILS
Miniature Circuit Breakers
Miniature Circuit Breakers-Wenzhou Kunji Trading