What Is a Tap Changer in a Transformer?

  • Tuesday, 13 May 2025
  • 0
  • 1204
  • 0

What Is a Tap Changer in a Transformer?

In a transformer, a tap changer is a device that connects or disconnects different taps on the regulating winding.tap changer in transformer This can alter the turns ratio of the transformer and adjust the resulting voltage level.

Most power transformers use load tap changers (OLTC) to vary their voltage levels.tap changer in transformer The OLTC consists of a group of tap positions on a regulating winding in the tank and control circuitry to facilitate the operation of these switches. When the OLTC needs to change voltage, the controls signal a sequence of steps to be followed in order to achieve the desired result. These controls can be motor-driven or manual, depending on the design of the particular OLTC. A failure of the operating mechanism can cause severe damage to the OLTC and the transformer.

Each OLTC has a number of raise and lower positions, which are interconnected by multipoint switches.tap changer in transformer These switches can be mechanically or electrically operated, with the latter being the most common. The operating mechanism is usually motor-driven, although a manual mode can be employed in the event of a motor failure. Each tap change has a maximum amount of current that can pass through the switch, and there is a limit on how many tap changes can be performed before the switching contacts begin to damage each other. This is why a variety of tests are available to detect problems with the OLTCs, which can be due to dielectric failures (oil quality or clearance related), thermal problems, mechanical issues such as contact wear and misalignment, sheared pins on the linkage that operates the reversing switch, and other causes.

The OLTC is the most common form of voltage control in power systems.tap changer in transformer It is a make before break switch that changes the physical tap position on the regulating winding, which is connected in series with the main winding to form the transformer low-voltage circuit. The OLTC also has control circuitry to assess the need for a raised or lowered tap change to maintain the rated voltage.

Circulating current control schemes have been used to minimize the stress on the OLTC during tap changing.tap changer in transformer However, these methods require the same number of points in each tap changer and are not as reliable as other tap changing schemes. They also suffer from the problem of one relay in a group not following the others, causing an imbalance of ratio.

To avoid this, all on-load tap changers have a fixed impedance in the main circuit connections that limits short circuit current between adjacent taps. The impedance could be a resistor or a reactor. These impedances must be exercised on a regular basis to ensure that they continue to function properly during the tapping process. Failure to exercise the impedances will lead to a high current in the main circuit, which could damage the transformer bushing insulators. This is a reason why all on-load tap changers include an emergency switch to prevent these currents from running.

Tags:rmu transformer | transformer parts | oltc transformer