How to Analyze Zero Sequence Current in Three-Phase Power Systems
How to Analyze Zero Sequence Current in Three-Phase Power Systems
Zero sequence current is a common term used to describe unbalanced phase-to-neutral or line-to-ground fault currents in three-phase power systems. The concept of zero sequence current is central to understanding how to analyze a three-phase balanced network under abnormal conditions and in the event of a fault. It is also critical to ensuring that protection equipment responds to and detects the presence of zero sequence currents.
The zero sequence current calculation can be a complex one, but in the end it’s really just a matter of adding up the vectors for each individual phase. As long as the phases are equal in magnitude and in phase, the result is that the total current in each phase will pass through each of the three phases equally and return by either the neutral or ground paths (Kirchoff’s Current Law).
A balance symmetrical three-phase circuit is defined as one with balanced, 120o displaced, equal-magnitude, three-phase source and balanced three-phase load networks. Under normal conditions, only positive sequence voltages and currents are excited in the circuit. When a fault occurs, it upsets this symmetry, and negative and zero sequence voltages and currents may be excited as well.
To understand the effect of a fault on the voltages and currents in the balanced portion of the three-phase system, engineers use the method of calculating symmetrical components to separate the system into its balanced and unbalanced portions. The sequence networks for each of the three phases are modeled as a Thevenin equivalent network, and a solution for these networks gives us a way to determine the voltages and currents that would normally exist in a balanced, unfaulted three-phase circuit.
When a fault occurs, the zero sequence current is divided between the three phases and the neutral or ground path as shown below. As a result, each of the three phase currents will pass through the faulted point in the system, and as a consequence, their vector sum will increase. This change in vector sum can be detected by the familiar methods of zero-sequence current detection and residual current protection.
Zero-sequence current protection can be applied to a delta or pure delta system, but is not possible in a star or mixed rated system because there is not a third neutral conductor present. The reason for this is that for zero sequence current to flow in a three-phase system, there must be a return path through a fourth conductor.
Zero-sequence current is a valuable tool in power system analysis because it allows for the detection of unbalanced and harmonic currents, which may be causing damage to equipment or operating problems for customers. The knowledge of zero sequence current can help designers and engineers ensure that their equipment will operate safely and reliably under all expected and unexpected circumstances. If you want to learn more about how to apply this important concept in your design work, check out our free eBook on Zero Sequence Current Calculation. We look forward to seeing you there!