KUNJI
Indoor AC High Voltage 12kv Load Switch Three-Phase Switchgear
Product Description
Customized products can consult online customer service!
FKN12-12D/T630-20 type indoor AC high-voltage load switch (referred to as FKN12-12D load switch) is a three-phase high-voltage switch with a rated voltage of 12KV and a rated frequency of 50Hz, which is used to divide the load current, closed-loop current, no-load transformer and cable charging current, and close the short-circuit current. Load switches equipped with ground switches can withstand short-circuit current.
F K N 12(1) A - 12(2) D / T 630 - 20
F:Load Switch
D:Ground Switch
K:Air Medium
T:Spring Mechanism
N:Indoor
630:Rated Current(A)
12(1):Design Number
20:Rated Short-time Withstand Current(KA)
A:Derived Code
12(2):Rated Voltage(KV)
F K R N 12(1) A - 12(2) D / T 125 - 31.5
F:Load Switch
12(2):Rated Voltage
K:Air Medium
D:Ground Switch
R:Fuse
T:Spring Mechanism
N:Indoor
125:Rated Current Of The Fuse A:Derived Code
12(1):Design Number
31.5:Rated Short-circuit Breaking Current(KA)
F:Load Switch
D:Ground Switch
K:Air Medium
T:Spring Mechanism
N:Indoor
630:Rated Current(A)
12(1):Design Number
20:Rated Short-time Withstand Current(KA)
A:Derived Code
12(2):Rated Voltage(KV)
F K R N 12(1) A - 12(2) D / T 125 - 31.5
F:Load Switch
12(2):Rated Voltage
K:Air Medium
D:Ground Switch
R:Fuse
T:Spring Mechanism
N:Indoor
125:Rated Current Of The Fuse A:Derived Code
12(1):Design Number
31.5:Rated Short-circuit Breaking Current(KA)
Environmental Conditions Of Use:
1. Ambient air temperature: -25ºC ~ +40ºC;
2. Poster height does not exceed 1000m;
3. The daily average relative humidity is not more than 95%, the monthly average is not more than 90%;
4. The earthquake intensity does not exceed 8 magnitude;
5. No fire, explosion risk, chemical corrosion and violent vibration places;
6. Pollution level: ‖
Structural Features:
1. Load switch, ground switch, fuse and mechanism in a frame, flexible combination, compact structure, small size, easy to install;
2. The fracture is arranged in direct motion, the dynamic and thermal stable current parameter is high, and the operation is completed at one time;
3. With static contact insulation cover, the ring network cabinet is isolated in the structure, eliminating the phase-to-phase insulation partition and the fracture insulation board, which can prevent the arc short circuit accident in the cabinet;
4. With unique valve structure, after the load switch is opened, the valve will automatically isolate the fracture, and the protection performance is good;
5. There is a reliable mechanical locking device between the load switch and the ground switch and the fuse to meet the requirements of "five defenses";
6. There are two forms of electric operation with manual operation and AC/DC dual operation power supply, which is easy to achieve the power system: "three remote" requirements.
| Serial Number | item | Unit | FKN12A-12D | FKRN12A-12D | ||
| 1 | Rated voltage | KV | 12 | 12 | ||
| 2 | Rated frequency | Hz | 50 | 50 | ||
| 3 | Rated current | A | 630 | 125 | ||
| 4 | Rated insulation level | 1min power frequency withstand voltage | To the ground, alternate | KV | 42 | 42 |
| Isolation fracture | 48 | 48 | ||||
| Lightning impulse withstand voltage (peak) | To the ground, alternate | 75 | 75 | |||
| Isolation fracture | 85 | 85 | ||||
| 5 | Load switch | KA | 20 | - | ||
| Ground switch | 20 | 20 | ||||
| 6 | Load switch | S | 4 | - | ||
| Ground switch | 2 | 2 | ||||
| 7 | Rated short circuit closing current (peak) | KA | 50 | - | ||
| 8 | Rated breaking current | Active load breaking current | A | 630 | - | |
| Closed-loop breaking current | 630 | - | ||||
| 5% active load breaking current | 31.5 | - | ||||
| Cable charging current | 10 | - | ||||
| Disconnect no-load transformer capacity | KVA | 1250 | 1250 | |||
| 9 | Rated short-circuit breaking current(current limiting fuse) | KA | - | 31.5 | ||
| 10 | Rated transfer current | A | - | 1200 | ||
| 11 | Mechanical life | Times | 2000 | 2000 | ||
| 12 | The kicker outputs power | J | - | 1+0.5 | ||
When placing order, please provide the following technical parameters
1. kV rated voltage:
2. rated voltage;
3. Combination of three levels, accurate phase and accurate;
4. rated output, and the corresponding accurate level (VA).
FAQ:
1: Are you a trading company or manufacturer ?
We are a professional factory with 7 years experience in the field of high and low voltage power transformers, substation, vacuum circuit breaker, power equipment.
2: Do you accept customized serveice ?
We offer OEM/ODM service , can print your logo on product . our professional technical and quotation team can provice a satisfied project according to your drawing and parameters .
7: What is your payment terms ?
30%T/T in adcance,70% before shipment . West union , L/C are also acceptable .
2: Do you accept customized serveice ?
We offer OEM/ODM service , can print your logo on product . our professional technical and quotation team can provice a satisfied project according to your drawing and parameters .
3: What is your MOQ?
Our MOQ is 1 piece.
Our MOQ is 1 piece.
4: How long is your delivery lead time ?
It depends on your product requirement and quantity . Generally , 5~10 working days is avaliable .
It depends on your product requirement and quantity . Generally , 5~10 working days is avaliable .
5: How do you solve quality problems?
Please porvide detailed photoes of quality problems. our technical and quality testing department will analyse.we will make asatisfied soluton within 2 days .
Please porvide detailed photoes of quality problems. our technical and quality testing department will analyse.we will make asatisfied soluton within 2 days .
6: What is the price of shipping?
Depending upon the port of delivery, prices varies.
Depending upon the port of delivery, prices varies.
7: What is your payment terms ?
30%T/T in adcance,70% before shipment . West union , L/C are also acceptable .
- Model NO.:
- FKN12A-12/FKRN12A-12
- Arc-extinguishing Medium:
- Vacuum
- Installation:
- Fixed
- Type:
- Circuit Breaker
- Function:
- Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection)
- Certification:
- ISO9001-2000, CE, CCC
- Rated Voltage:
- 36kv
- Installation Method:
- Withdrawable
- Rated Current:
- 630A/1250A
- Rated Frequency:
- 50/60Hz
- Material:
- Steel, Expoxy Resin
- Mechanical Life:
- 10,000 Times
- Certificate:
- IEC CE CCC
- Transport Package:
- Cartons/Wooden Cases
- Trademark:
- KUNJI-ELECTRIC
- Origin:
- Zhejiang, China
- HS Code:
- 8537209000
- Production Capacity:
- 2000 Piece/Pieces Per Month
- Package Size:
- 70.00cm * 40.00cm * 82.00cm
- Package Gross Weight:
- 120.000kg